Step | | Procedure & Parts & Tools |
1 |
|
PULL DOWN ON THE HANDLE RELEASE LEVER AND LIFT UP ON HANDLE TO REMOVE IT.
|
2 |
|
REMOVE THE 6 SCREWS IN BACK OF HANDLE.
Screwdriver-phillips |
|
|
3 |
|
LIFT UP ON THE BACK OF HANDLE TO SEPARATE FROM THE FRONT OF HANDLE.
|
4 |
|
FLIP THE WIRE COVER DOWN TO EXPOSE THE THERMAL PROTECTOR WIRES.
|
5 |
|
SLIDE THE THERMAL PROTECTOR (YELLOW WIRES) OUT OF PUMP. REMOVE THE YELLOW WIRE CONNECTOR FROM THE PUMP. INSERT THE VOLT METER LEAD IN WIRE CONNECTOR.
Volt meter (True RMS capable) |
|
|
6 |
|
REMOVE THE YELLOW WIRE CONNECTOR FROM THE PRESSURE SWITCH. INSERT THE VOLT METER LEAD INTO THE WIRE CONNECTOR. (DOESNT MATTER WHICH LEAD GOES WHERE). SET THE VOLT METER TO CONTINUITY. IF THE VOLT METER BEEPS, THE THERMAL PROTECTOR IS OKAY. REVERSE STEPS 1 THRU 6 TO REASSEMBLE THE MACHINE.
Volt meter (True RMS capable) |
|
|